Supermicro Inc. SYS-6038R-TXR SPECpower_ssj2008 = 8,274 overall ssj_ops/watt
Test Sponsor: Supermicro Inc SPEC License #: 1176 Test Method: Single Node
Tested By: Supermicro Inc. Test Location: Chung-Ho Dist,TW, R.O.C Test Date: Apr 14, 2015
Hardware Availability: Jan-2015 Software Availability: Jun-2013 Publication: Jun 2, 2015
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.6% 3,164,328 303 10,442
90% 90.0% 2,858,968 279 10,237
80% 79.9% 2,538,260 257 9,890
70% 70.0% 2,224,652 233 9,534
60% 60.0% 1,905,961 209 9,123
50% 50.0% 1,589,054 187 8,483
40% 40.0% 1,270,247 167 7,628
30% 30.1% 956,240 148 6,446
20% 20.0% 636,825 131 4,864
10% 10.0% 317,613 114 2,796
Active Idle 0 82.5 0
∑ssj_ops / ∑power = 8,274
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Supermicro Inc.
Model: SYS-6038R-TXR
Form Factor: 3U
CPU Name: Intel Xeon E5-2699 V3
CPU Characteristics: 18 Core, 2.3GHz, 45MB L3 cache
CPU Frequency (MHz): 2300
CPU(s) Enabled: 36 cores, 2 chips, 18 cores/chip
Hardware Threads: 72 (2 / core)
CPU(s) Orderable: 1,2 chipS
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 45 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 64
# and size of DIMM: 16 x 4096 MB
Memory Details: 4GB 1Rx8 PC4-2133P; A1,A2,B1,B2,C1,C2,D1,D2,E1,E2,F1,F2,G1,G2,H1,H2 populated.
Power Supply Quantity and Rating (W): 1 x 980
Power Supply Details: PWS-982-1R
Disk Drive: 1 x Seagate SATA III 100 GB SSD 9XW152-003
Disk Controller: onboard SCU controller
# and type of Network Interface Cards (NICs) Installed: 1 x Dual-port Onboard Intel I350 Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 2/1/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Power Saver
Operating System (OS): Microsoft Windows Server Enterprise 2008 R2 SP1
OS Version: 6.1.7601 Build 7601 (64-bit)
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6, JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 (JIT enabled, AOT enabled))
JVM Command-line Options: -Xmn1690m -Xms2048m -Xmx2048m-Xaggressive -Xcompressedrefs -Xgcpolicy:gencon -XlockReservation -Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0 -Xthr:minimizeusercpu -Xgcthreads6
JVM Affinity: start /NODE [0,1,2,3] /AFFINITY [3F,FC0,3F000]
JVM Instances: 12
JVM Initial Heap (MB): 2048
JVM Maximum Heap (MB): 2048
JVM Address Bits: 64
Boot Firmware Version: X10DRX5.326
Management Firmware Version: 01.91
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: IBM WebSphere Application Server V8.5.0.0, Microsoft Hotfix for Windows (KB2510206)
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Supermicro
Model: X8SIA
CPU Description: I7 880 3.07G
Memory amount (GB): 8
Software
Operating System (OS): Windows Server 2008 R2 Enterprise Edition
JVM Vendor: Oracle Corporation
JVM Version: Jave(TM) SE Runtime Environment (build 1.7.0_04-b22) Java HotSpot(TM) 64-Bit Server VM(build 23.0-b21)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Meters and Instruments Corporation.
Model: WT210
Serial Number: 91M620744
Connectivity: Serial
Input Connection: Default
Metrology Institute: NML (National Measurement Laboratory)
Accredited by: Omnio Calibration Lab. Co., Ltd.
Calibration Label: OCL-2351503H12C7
Date of Calibration: 13-Mar-2015
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.7.0-538b1562-20140802
Setup Description: Connected to PSU
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 10 mm in front of SUT main air intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 303 20.5
90% 279 20.5
80% 257 20.5
70% 233 20.5
60% 209 20.5
50% 187 20.5
40% 167 20.5
30% 148 20.5
20% 131 20.5
10% 114 20.5
Active Idle 82.5 20.4
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 20.4 10
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     3,148,592
Calibration 2     3,177,619
Calibration 3     3,178,936
ssj_ops@calibrated=3,178,277
100% 99.6% 3,178,277 3,164,328
90% 90.0% 2,860,450 2,858,968
80% 79.9% 2,542,622 2,538,260
70% 70.0% 2,224,794 2,224,652
60% 60.0% 1,906,966 1,905,961
50% 50.0% 1,589,139 1,589,054
40% 40.0% 1,271,311 1,270,247
30% 30.1% 953,483 956,240
20% 20.0% 635,655 636,825
10% 10.0% 317,828 317,613
Active Idle   0 0
Graph of results